- Frequency range from 50 KHz to 500 KHz.
- Current ratings up to 2 Amp.
- Excellent attenuation in common mode.
- Inductance values from 0.6 mH to 14 mH.
- Leakage Inductance less than 10% of inductance value.
- 3 mm of creepage between windings.
- Parts meet UL, IEC950 & VDE safety standards.
|
MEDIUM Z RANGE - UU10 7K |
FALCO PART NUMBER |
RoHS Part Number |
L (mH)1 MIN |
Freq. (KHz) |
DCR (W) MAX |
Irms (Amp)2 MAX |
 U10008 |
|
0.60 |
1.0 |
0.150 |
2.00 |
|
 U10009** |
0.90 |
1.0 |
0.120 |
2.50 |
 U10012 |
|
2.00 |
1.0 |
0.400 |
1.00 |
 U10013 |
|
10.00 |
1.0 |
0.770 |
0.60 |
 U10001 |
|
14.00 |
10.0 |
1.400 |
0.51 |
HIGH Z RANGE - UU10 10K |
FALCO PART NUMBER |
RoHS Part Number |
L (mH)1 MIN |
Freq. (KHz) |
DCR (W) MAX |
Irms (Amp)2 MAX |
 U10014 |
|
3.00 |
1.0 |
0.200 |
1.00 |
|
 U10016 |
5.50 |
1.0 |
0.245 |
1.400 |
 U10005* |
 U10L05* |
6.00 |
1.0 |
0.500 |
0.90 |
 U10015* |
|
8.20 |
1.0 |
0.310 |
0.70 |
 U10010** |
|
36.00 |
1.0 |
1.920 |
0.45 |
*2.2 mm of creepage between windings. **Bobbin has 4 sections.
1. Inductance tested at 0.25 V.
2. Temperature rise is 40°C Typ.
3. Operating Temp. range -40°C to +105°C.
4. OCL and DCR tested at Ta=25°C.
|