- For sensing and monitoring in analog systems
and DC/DC converters.
- Surface mount design.
- Primary rating current up to 10 Amps.
- Operating frequency range from 10 kHz and extended
to 450 KHz for some applications.
- Built to meet temperature class F (155°C)
|
FALCO PART NUMBER |
RoHS PART NUMBER |
Turns Ratio Np: Ns |
L (µH) min |
DCR (W) max. |
Hipot (Vrms) 1 sec |
Rt (W) |
Dot Color Code |
Ipk (Amps.) |
 E05015 |
|
1 :20 |
80 |
0.54 |
500 |
2.0 |
Brown |
10 |
 E05016 |
 E05L16 |
1: 50 |
500 |
1.50 |
500 |
5.0 |
Red |
10 |
 E05017 |
|
1: 70 |
980 |
4.72 |
500 |
7.0 |
Blue |
10 |
 E05018 |
 E05L18 |
1:100 |
2000 |
5.50 |
500 |
10.0 |
White |
10 |
|
1. Inductance tested at 10 kHz & 0.25 V.
2. L and DCR tested at 25°C.
3. Hipot tested between primary and secondary to core.
4. Rt is the terminating resistor on the secondary winding (not included ) for a 0.1 V/A sensing ratio .
5. Operating Temp. Range -40°C to +125°C.
6. In order to prevent saturation keep Bmax below 2000 Gauss. K=1 for Unipolar waveform : K=2 for Bipolar waveform in formulae.
7. Temperature rise (°C): 290* (Pcu + Pfe) Watts.
|