- Used as ouput choke in switch mode power supplies, switching
regulators and audio filters.
- Handle up to 14 Amps.
- Inductance available from 2.2 µH to 220 µH.
- Complies with UL, CSA, IEC standards.
|
FALCO PART NUMBER |
RoHS Part Number |
L(µH)1 ±10% |
Freq. (KHz) |
DCR (W) max. |
Isat (ADC)2 max. |
Irms (amp)3 max. |
|
 D14002 |
22.00 |
1.0 |
0.018 |
14.00 |
9.10 |
 D14001 |
|
30.50 |
10.0 |
0.028 |
12.00 |
5.00 |
 D14004* |
|
100.00 |
10.0 |
0.085 |
7.00 |
2.00 |
 D14A04* |
|
100.00 |
10.0 |
0.085 |
7.00 |
2.00 |
|
 D14L04 |
100.00 |
10.0 |
0.085 |
7.00 |
2.00 |
|
 D14005** |
200.00 |
1.0 |
0.175 |
5.50 |
3.20 |
 D14003 |
|
220.00 |
1.0 |
0.240 |
5.00 |
2.10 |
*C DIMENSION TOLERANCE ± 0.020[0.50]
|
1. Inductance L tested at 0.25 V. **LTOLERANCE±15%
2. Inductance drop 10% typ. at Isat.
3. Temperature rise is 40°C Typ at rated current.
4. L and DCR tested at Ta= 25°C.
|