50/60 Hz Line Transformers E-I 30 x 12.5 mm
1.5 VA Series

POWER MAGNETICS (OLD) | Back

PDF File PDF File
  • Power rating 1.5 VA
  • 115/230 Volts input at 50/60 Hz.
  • Single and dual inputs/outputs.
  • Vaccum potted.
  • Filling epoxy rated class B.
  • Dielectric strength test of 4000 Volts.
  • Flame retardant plastic case UL94V-0.

FALCO PART
NUMBER
Input Primary
(V)
Vo NO LOAD(V) Vo 1 @ Io (V) I o (mA) Primary Pins Secondary Pins Schematic

Single Primary / Single Secondary
 L30003 115 8.95 6.00 250 1-5 7-9 1
 L30004 115 11.90 9.0 166 1-5 7-9 1
 L30005 115 15.50 12.0 125 1-5 7-9 1
 L30006 115 20.40 15.0 100 1-5 7-9 1
 L30007 115 24.50 18.0 83 1-5 7-9 1
 L30008 115 31.50 24.0 62 1-5 7-9 1
 L30016 230 9.85 6.0 250 1-2 10-8 5
 L30025 230 11.50 9.0 166 1-5 7-9 1
 L30002 230 12.00 8.0 185 1-5 7-9 1
 L30026 230 15.50 12.0 125 1-5 7-9 1

Single Primary /Dual Secondary
 L30009 115 2 x 8.90 2 x 6.0 2 x 125 1-5 6-7, 9-10 2
 L30010 115 2 x 11.9 2 x 9.0 2 x 83 1-5 6-7, 9-10 2
 L30011 115 2 x 15.3 2 x 12 2 x 62 1-5 6-7, 9-10 2
 L30022 230 2 x 15.5 2 x 12 2 x 62.5 1-5 7-6,10-9 6
 L30024 230 2 x 20.4 2 x 15 2 x 50 1-5 7-6, 10-9 6

Dual Primary/ Single Secondary
 L30012 2 X 115 8.90 6.0 250 1-2, 4-5 7-9 3
 L30013 2 X 115 11.50 9.0 166 1-2, 4-5 7-9 3

Dual Primary/ Dual Secondary
 L30014 2 X 115 2 x 8.95 2 x 6.0 2 x 125 1-2, 4-5 6-7, 9-10 4
 L30015 2 X 115 2 x 12.3 2 x 9.0 2 x 83 1-2, 4-5 6-7, 9-10 4

1. Voltage tolernace of ±5%.
2. All voltages and current values are refered to rms ratings.
3. Power rating specified are for resistive load on secondary.
4. Operating temp. range -20 to +105°C.
5. Care should be taken in order to prevent ambient plus self heating temperature rise does not exceed operating temperature limits.