- For use in electronic watt-hour meter applications
- 120/240V 50/60 Hz in single and polyphase applications
- Class 20/200/320Ampere rating (ANSI 0.2, 0.5)
- Epoxy or tape wrapped coil protection
|
FALCO PART NUMBER |
L(H) |
Tol. |
FREC. (Hz) |
Turns Ratio |
DCR (W) NOM. |
Irms max (A) |
 T50111 |
35.0 |
Min. |
50 |
1:1500 |
46 |
20 |
 T75012 |
238.0 |
±30% |
50 |
1:2000 |
114 |
50 |
 T14049 |
60.0 |
Min. |
120 |
1:2000 |
25 |
200 |
 T16013 |
55.0 |
Min. |
120 |
1:2000 |
22 |
320 |
 T17004 |
200.0 |
Min. |
60 |
1:4000 |
66 |
640 |
1. L & DCR tested at Ta= 25°C
2. Turns tolerance is ± 1.0 % typ
3. Operating Temperature Range: -40°C to +85°C
|